Open Access

Table A.3

Description of the catalogue FITS table. PL stands for Power Law and LP for LogParabola.

Column Units description
Source_Name Source name (HESS JHHmm±DDd identifier)
RAJ2000 deg Right Ascension (J2000)
DECJ2000 deg Declination (J2000)
nON Number of events in the ON region
nOFF Number of events in the OFF regions
Alpha Normalisation of the OFF regions
LiMa_Significance Detection Significance
LiveTime h Live time in hours
Flux_Spec_PL_Diff_Pivot cm−2 s−1 TeV−1 Differential flux at pivot energy
Flux_Spec_PL_Diff_Pivot_Err cm−2 s−1 TeV−1 Statistical error (1 sigma) on Flux_Spec_PL_Diff_Pivot
Index_Spec_PL Spectral index
Index_Spec_PL_Err Statistical error (1 sigma) on Index_Spec_PL
Pivot_Energy TeV Pivot energy
Spectral_Model Preferred spectral model
Emin_Spectrum TeV Minimal energy of the spectrum
Emax_Spectrum TeV Maximal energy of the spectrum
Flux_Spec_LP_Diff_Pivot cm−2 s−1 TeV−1 Differential flux at pivot energy
Flux_Spec_LP_Diff_Pivot_Err cm−2 s−1 TeV−1 Statistical error (1 sigma) on Flux_Spec_LP_Diff_Pivot
Alpha_Spec_LP Spectral index
Alpha_Spec_LP_Err Statistical error (1 sigma) on Alpha_Spec_LP
Beta_Spec_LP Curvature value
Beta_Spec_LP_Err Statistical error (1 sigma) on Beta_Spec_LP_Err
Flux_Spec_PL_Diff_Pivot_EBL cm−2 s−1 TeV−1 Differential flux at pivot energy
Flux_Spec_PL_Diff_Pivot_Err_EBL cm−2 s−1 TeV−1 Statistical error (1 sigma) on Flux_Spec_LP_Diff_Pivot_EBL
Index_Spec_PL_EBL Spectral index, EBL corrected
Index_Spec_PL_Err_EBL Statistical error (1 sigma) on Index_Spec_PL_EBL
Pivot_Energy_EBL TeV Pivot energy
Redshift Redshift of the source
Energy TeV centre of the energy bin
Delta_Energy_Up TeV high energy bound of the energy bin
Delta_Energy_Low TeV low energy bound of the energy bin
Differential_Flux cm−2 s−1 TeV−1 differential flux at Energy
Differential_Flux_Err cm−2 s−1 TeV−1 Statistical error (1 sigma) on Differential_Flux, 0 if upper limit
Time_MJD d Time in days of the Light curve point (only for sources identified as variable)
Flux_above_300GeV cm−2 s−1 Integral flux above 300 GeV
Flux_above_300GeV_Err cm−2 s−1 Statistical error (1 sigma) on Integral flux above 300 GeV

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.