Open Access

Table 3.

Properties of the shock tests described in Sects. 3.1 to 3.3.

Test/Parameter Lbox Ncells Δx ρ0 vx, 0 T0 By, 0 Cooling CT
(Unit) (1016 cm) (1012 cm) (10−23 g cm−3) (km s−1) (K) (G)
Shock Test 1a 5.0 1024 4.8828E+1 2.0374 -100 1.0E+4 1.0E−6 No No
Shock Test 1b 5.0 10240 4.8828E+0 2.0374 -100 1.0E+4 1.0E−6 No No
Shock Test 2 104 1536 6.5104E+4 5.0935 -1000 1.0E+4 1.0E−6 Yes No
Shock Test 3a 1.0 10240 9.7660E−1 5.0935 -1000 1.0E+4 1.0E−6 Yes No
Shock Test 3b 1.0 10240 9.7660E−1 5.0935 -3000 1.0E+4 1.0E−6 Yes No
Shock Test 4 0.3 256 1.1719E+1 2.0374 -120 1.0E+4 1.0E−6 Yes Yes

Notes. Column meanings are: Lbox is the length of the x-domain. Ncells is the number of grid cells spanning this domain (uniform grid), Δx = Lbox/Ncells, ρ0, vx, 0, T0 and By, 0 are the uniform initial conditions, and the last two columns indicate whether or not radiative cooling and charge-transfer (CT) reactions are included.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.