Table 3
Performance and capabilities improved from MATISSE to current GRA4MAT, and future planned improvements when GPAO becomes available on the UTs.
Metric | MATISSE | GRA4MAT | GRA4MAT+GPAO | ||
---|---|---|---|---|---|
L-band spectral resolution and instantaneous coverage | |||||
LM low (R ~ 35, 2.9 µm to 5.0 µm) | 100% | 100% | |||
LM medium (R ~ 500, 2.9 µm to 5.0 µm) | 6.4% 0.16µm | 100% | Sect. 4.1 | ||
L high (R ~ 1000, 2.9 µm to 4.2 µm) | 6.4% 0.8 µm | 100% | |||
L high+ (R ~ 3300, 4.02 µm to 5.0 µm) | 0% | 100% | |||
Detector integration time (s) | |||||
L low | 1 | 1 | |||
L medium | 8.5 | 10 | Sect. 4.2 | ||
L high | Not offered | 10 | |||
L high+ | Not offered | 10 | |||
M low | 2 | 0.7 | |||
M medium | 13 | 11 | Sect. 4.2 | ||
M high+ | Not offered | 17 | |||
N low | 17 | 3 | |||
N high | Not offered | 26 | |||
AT correlated flux sensitivity within 30% best conditions (Jy) | |||||
L low | 1 | 0.2 | |||
L medium | 8.5 | 1 | Sect. 4.2 | ||
L high | Not offered | 2 | |||
L high+ | Not offered | 10 | |||
M low | 2 | 0.7 | |||
M medium | 13 | 11 | Sect. 4.2 | ||
M high+ | Not offered | 17 | |||
N low | 17 | 3 | |||
N high | Not offered | 26 | Set. 4.3 | ||
UT correlated flux sensitivity within 30% best conditions (Jy) | |||||
L low | 0.06 | 0.02 | 0.01 | ||
L medium | 0.6 | 0.3 | Sect. 4.2 | 0.05 | Sect. 5.2 |
L high | Not offered | 0.7 | 0.1 | ||
L high+ | Not offered | 6 | 0.5 | ||
M low | 0.5 | 0.07 | 0.035 | ||
M medium | 1.3 | 1 | Sect. 4.2 | 0.55 | Sect. 5.2 |
M high+ | Not offered | 6 | 0.85 | ||
N low | 0.9 | 0.1 | Sect. 4.3 | ||
N high | Not offered | 0.5 | |||
Raw contrast | |||||
30% best conditions | 0.85 ± 0.06 | 0.93 ± 0.02 | |||
50% best conditions | 0.81 ± 0.08 | 0.93 ± 0.02 | Sect. 4.4 | ||
Observing capabilities | |||||
AT chopping: photometry & visibility | Yes | Yes | |||
UT chopping: photometry & visibility | Yes | No | Sect. 2.6 | Yes | Sect. 5.2 |
Narrow off-axis observations | No | Yes | Sect. 2.5 |
Notes. Detailed explanations are available in the referenced §X.X sections. More updated values, covering a wider range of atmospheric conditions, are available on the VLTI/MATISSE instrument page of the ESO website (https://www.eso.org/sci/facilities/paranal/instruments/matisse.html).
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.