Table 1.

Main modeling parameters for the three different models tested in this work (PFSS, WP, and WP-AW).

Input parameters PFSS WP WP-AW
max (cut-off harmonics of input map) 30 30 25
μ (multiplying factor of input map) 1 0.3 1
Domain (r[R] × θ[rad] × φ[rad]) [0, 2.5]×[0, π]×[0, 2π] [0, 30]×[0, π]×[0, 2π] [0, 30]×[0.05, 3.09]×[0, 2π]
Grid (r × θ × φ) 12 × 92 × 184 172 × 86 × 172 182 × 160 × 320
Specific parameters Rss = 2.5 R γ = 1.03 , c s v esc = 0.26 $ \gamma=1.03, \frac{c_{\mathrm{s}}}{v_{\mathrm{esc}}}=0.26 $ Fh = 2104 cgs,κ0 = 910−7 cgs,
δv = 12 km s−1, Tc = 2 104 K
Numerical methods N/A HLLD, divergence cleaning HLL, constrained transport

Notes. For each model, we specify the input parameters related to the input magnetic map (cut-off harmonics max and multiplying factor μ). We also specify parameters regarding the simulation domain and the grid resolution. Finally, we specify the parameters that are characteristic of each model. We end with the main numerical methods used, when it is relevant. For a more precise definition of each parameter, see Appendix B.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.