Residuals in demodulated flat-field frames per Stokes parameter as mean peak to valley variation within a continuum region after dark field correction and after applying the spectroflat flat-field corrections to the flat-field data themselves.

Instrument D(FF′) D(FF(1))
TRIPPLE-SP I 25.26 3.52
(SST) Q/I 0.58 0.07
U/I 0.85 0.09
V/I 0.66 0.07

SUSI I 27.20 25.01
(SUNRISE-III) Q/I 0.63 0.06
U/I 0.45 0.15
V/I 0.54 0.24

GRIS I 49.23 5.22
(GREGOR) Q/I 0.49 0.18
U/I 0.32 0.17
V/I 0.71 0.18

Notes. Reduction symbols as in Sect. 2.6, values are 10−2.