Open Access

Table C.1

Parameters relative to the frank fits at each wavelength.

λ [mm] α wsmooth B80 [kλ] θ [arcsec]
0.89 1.1 0.001 2600 0.08
1.3 1.3 0.001 2940 0.07
2.0 1.1 0.01 2580 0.08
3.0 1.2 0.1 2240 0.09
9.1* 1.5 1.0 2180 0.09
30* 1.05 0.001 620 0.33

Notes. α and wsmooth are the hyperparameters used for the retrieval of the brightness profiles with frank. The last two columns report the baseline up to which the model reproduces the visibilities within 20% (B80), and the corresponding spatial scale. The rows marked with a* symbol highlight the datasets that have been first corrected for a central compact emission.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.