Table 2.
VLA observations and measurements.
Source | Band | Obs date | ton | Complex gain calibrator | Flux density scale calibrator | Beam size | Sint | Speak |
---|---|---|---|---|---|---|---|---|
(s) | (arc sec2) | (mJy) | (mJy beam−1) | |||||
(1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) |
J0131−0321 | S | 2019 August 14 | 116 | J0125−0005 | 3C138 | 0.74 × 0.52 | 60.57 ± 0.11 | 59.64 ± 0.06 |
C | 2019 August 08 | 116 | J0125−0005 | 3C138 | 0.51 × 0.29 | 43.34 ± 0.11 | 43.15 ± 0.06 | |
X | 2019 August 07 | 118 | J0125−0005 | 3C138 | 0.24 × 0.17 | 31.81 ± 0.18 | 31.72 ± 0.10 | |
J0741+2520 | S | 2019 September 07 | 136 | J0741+2706 | 3C147 | 0.58 × 0.53 | 3.89 ± 0.05 | 3.89 ± 0.03 |
C | 2019 August 30 | 138 | J0741+2706 | 3C147 | 0.30 × 0.28 | 3.27 ± 0.03 | 3.22 ± 0.02 | |
X | 2019 August 30 | 208 | J0741+2706 | 3C147 | 0.18 × 0.17 | 2.46 ± 0.02 | 2.46 ± 0.01 | |
J1034+2033 | S | 2019 September 07 | 138 | J1051+2119 | 3C147 | 0.76 × 0.57 | 3.94 ± 0.06 | 4.00 ± 0.03 |
C | 2019 August 30 | 136 | J1051+2119 | 3C147 | 0.38 × 0.29 | 2.92 ± 0.04 | 2.85 ± 0.02 | |
X | 2019 August 30 | 138 | J1051+2119 | 3C147 | 0.26 × 0.18 | 1.88 ± 0.03 | 1.89 ± 0.02 | |
J1146+4037 | S | 2019 September 07 | 128 | J1146+3958 | 3C147 | 0.87 × 0.55 | 11.05 ± 0.06 | 10.76 ± 0.03 |
C | 2019 August 30 | 128 | J1146+3958 | 3C147 | 0.43 × 0.28 | 9.51 ± 0.03 | 9.46 ± 0.02 | |
X | 2019 August 30 | 126 | J1146+3958 | 3C147 | 0.30 × 0.17 | 7.59 ± 0.04 | 7.51 ± 0.02 | |
J1614+4640 | S | 2019 September 02 | 118 | J1613+3412 | 3C48 | 0.90 × 0.54 | 4.06 ± 0.16 | 3.84 ± 0.09 |
C | 2019 August 14 | 148 | J1613+3412 | 3C48 | 0.42 × 0.27 | 3.13 ± 0.08 | 3.07 ± 0.04 | |
X | 2019 August 11 | 148 | J1613+3412 | 3C48 | 0.31 × 0.19 | 1.96 ± 0.10 | 1.80 ± 0.05 | |
J2228+0110 | S | 2019 September 02 | 136 | J2212+0152 | 3C48 | 0.72 × 0.54 | 0.24 ± 0.07 | 0.16 ± 0.03 |
C | 2019 August 14 | 196 | J2212+0152 | 3C48 | 0.38 × 0.27 | 0.22 ± 0.03 | 0.21 ± 0.02 | |
X | 2019 August 11 | 206 | J2212+0152 | 3C48 | 0.22 × 0.18 | 0.19 ± 0.04 | 0.13 ± 0.02 | |
J2245+0024 | S | 2019 September 02 | 138 | J2247+0310 | 3C48 | 0.74 × 0.54 | 1.65 ± 0.06 | 1.61 ± 0.03 |
C | 2019 August 14 | 192 | J2247+0310 | 3C48 | 0.38 × 0.27 | 1.75 ± 0.03 | 1.73 ± 0.02 | |
X | 2019 August 11 | 208 | J2247+0310 | 3C48 | 0.22 × 0.18 | 1.40 ± 0.03 | 1.36 ± 0.02 |
Notes. Column 1: source name. Column 2: adopted VLA band. Column 3: observation date. Column 4: on-source integration time. Column 5: complex gain calibrator. Column 6: flux density scale calibrator. Column 7: the corresponding clean beam size for each observation. Columns 8−9: the integrated and peak flux density measured by the CASA 2D Gaussian tool. Errors shown here are fitting-type errors. During the model fitting in Sect. 3.1, we also considered additional 5% calibration errors.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.