Table 1.
Best-fit parameters for the different XSPEC model components used to fit the spectra of Fig. 10.
Model | ObsID 6868 | ObsID 6869 | ObsID 6870 | ObsID 6871 | ObsID 6872 | ObsID 6873 |
---|---|---|---|---|---|---|
(1) zpowerlw | ||||||
NH (1022 cm−2) | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Γ | ![]() |
2.10(t) | 2.10(t) | 2.10(t) | 2.10(t) | 2.10(t) |
A (10−2 cm−2 s−1 keV−1) | ![]() |
![]() |
![]() |
![]() |
1.07(t) | ![]() |
(2) pexrav | ||||||
A (10−2 cm−2 s−1 keV−1) | ![]() |
1.07(t) | 1.07(t) | 1.07(t) | 1.07(t) | 1.07(t) |
(3) zgauss(Fe I Kα em.) | ||||||
E (keV) | ![]() |
6.38(t) | 6.38(t) | 6.38(t) | 6.38(t) | 6.38(t) |
F (10−6 cm−2 s−1) | ![]() |
8.2(t) | 8.2(t) | 8.2(t) | 8.2(t) | 8.2(t) |
(4) zgauss(Fe XXV abs.) | ||||||
v (km s−1) | ![]() |
−4540(t) | −4540(t) | −4540(t) | −4540(t) | −4540(t) |
F (10−6 cm−2 s−1) | ![]() |
−15.4(t) | −15.4(t) | >−9.06 | 0 (f) | >−9.06(t) |
(5) zgauss(Fe XXVI abs.) | ||||||
v (km s−1) | −4540(t) | −4540(t) | −4540(t) | −4540(t) | −4540(t) | −4540(t) |
F (10−6 cm−2 s−1) | ![]() |
−9.8(t) | −9.8(t) | >−6.35 | 0 (f) | >−6.35(t) |
(6) vapec | ||||||
NH (1022 cm−2) | ![]() |
0.059(t) | 0.059(t) | 0.059(t) | 0.059(t) | 0.059(t) |
kT (keV) | ![]() |
0.66(t) | 0.66(t) | 0.66(t) | 0.66(t) | 0.66(t) |
ZO (Z⊙) | ![]() |
0.08(t) | 0.08(t) | 0.08(t) | 0.08(t) | 0.08(t) |
ZNe (Z⊙) | ![]() |
0.21(t) | 0.21(t) | 0.21(t) | 0.21(t) | 0.21(t) |
ZMg (Z⊙) | ![]() |
0.36(t) | 0.36(t) | 0.36(t) | 0.36(t) | 0.36(t) |
ZSi (Z⊙) | ![]() |
0.49(t) | 0.49(t) | 0.49(t) | 0.49(t) | 0.49(t) |
ZFe (Z⊙) | ![]() |
0.06(t) | 0.06(t) | 0.06(t) | 0.06(t) | 0.06(t) |
EM (1063 cm−3) | ![]() |
3.75(t) | 3.75(t) | 3.75(t) | 3.75(t) | 3.75(t) |
Notes. The table lists: primary (1) and reflected (2) AGN emission, Fe I Kα (E = 6.4 keV) emission line (3), Fe XXV (4; E = 6.7 keV) and Fe XXVI (5; E = 6.97 keV) absorption lines, thermal emission (6). NH: column density; Γ: power-law photon index; A: power-law normalization at 1 keV; F: integrated flux of the spectral line; kT: plasma temperature; Z: elemental abundance; EM: emission measure. (t) indicates tied parameters; (f) marks fixed parameters.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.