Free Access
Table B.1
Line parameters of HCO.
Transition | Frequency | E u / k | A ul | S ul | g u | ![]() |
![]() |
Δv |
![]() |
S / N |
|
||||||||||
(NKa,Kc,J,F)u → (NKa,Kc,J,F)l | [MHz] | [K] | [s-1] | [mK km s-1] | [km s-1] | [km s-1] | [mK] | |||
|
||||||||||
10,1, 3/2, 2 → 00,0, 1/2, 1 | 86 670.760F | 4.2 | 4.68 × 10-6 | 1.66 | 5 | 497(12) | 10.5(<0.1) | 3.1(0.1) | 149 | 52 |
10,1, 3/2, 1 → 00,0, 1/2, 0 | 86 708.360F | 4.2 | 4.59 × 10-6 | 0.98 | 3 | 286(7) | 10.5(<0.1) | 2.8(0.1) | 95 | 33 |
10,1, 1/2, 1 → 00,0, 1/2, 1 | 86 777.460F | 4.2 | 4.60 × 10-6 | 0.98 | 3 | 294(7) | 10.5(<0.1) | 3.0(0.1) | 92 | 32 |
10,1, 1/2, 0 → 00,0, 1/2, 1 | 86 805.780F | 4.2 | 4.71 × 10-6 | 0.33 | 1 | 75(6) | 10.5(0.1) | 2.3(0.2) | 31 | 10 |
20,2, 5/2, 3 → 10,1, 3/2, 2 | 173 377.377W | 12.5 | 4.50 × 10-5 | 2.80 | 7 | 683(86) | – | – | – | 8 |
20,2, 5/2, 2 → 10,1, 3/2, 1 | 173 406.082W | 12.5 | 4.42 × 10-5 | 1.96 | 5 | 346(70) | – | – | – | 6 |
20,2, 3/2, 2 → 10,1, 1/2, 1 | 173 443.065W | 12.5 | 3.38 × 10-5 | 1.50 | 5 | 409(94) | – | – | – | 5 |
20,2, 3/2, 1 → 10,1, 1/2, 0 | 173 474.400W | 12.5 | 2.50 × 10-5 | 0.66 | 3 | 185(79) | – | – | – | 4 |
30,3, 7/2, 4 → 20,2, 5/2, 3 | 260 060.329F | 25.0 | 1.63 × 10-4 | 3.85 | 9 | 576(15) | 10.5(<0.1) | 2.0(0.1) | 275 | 23 |
30,3, 7/2, 3 → 20,2, 5/2, 2 | 260 082.192F | 25.0 | 1.60 × 10-4 | 2.95 | 7 | 446(15) | 10.5(<0.1) | 2.0(0.1) | 209 | 16 |
30,3, 5/2, 3 → 20,2, 3/2, 2 | 260 133.586F | 25.0 | 1.45 × 10-4 | 2.67 | 7 | 347(17) | 10.6(<0.1) | 1.7(0.4) | 195 | 15 |
30,3, 5/2, 2 → 20,2, 3/2, 1 | 260 155.769W | 25.0 | 1.37 × 10-4 | 1.80 | 5 | 382(25) | – | – | – | 19 |
40,4, 9/2, 5 → 30,3, 7/2, 4 | 346 708.493F | 41.6 | 3.99 × 10-4 | 4.88 | 11 | 437(38) | 10.6(0.1) | 2.6(0.3) | 156 | 7 |
40,4, 9/2, 4 → 30,3, 7/2, 3 | 346 725.172F | 41.6 | 3.95 × 10-4 | 3.95 | 9 | 308(36) | 10.6(0.1) | 2.0(0.3) | 142 | 7 |
40,4, 7/2, 4 → 30,3, 5/2, 3 | 346 787.898F | 41.6 | 3.76 × 10-4 | 3.76 | 9 | 362(41) | 10.5(0.2) | 3.0(0.5) | 112 | 6 |
40,4, 7/2, 3 → 30,3, 5/2, 2 | 346 804.597F | 41.6 | 3.67 × 10-4 | 2.85 | 7 | 223(29) | 10.6(0.1) | 1.6(0.3) | 127 | 7 |
Notes. Frequencies, Eu/k, Aul, Sul, and gu from JPL catalogue. Labels: (F) Detected with FTS backend. (W) The lines detected with WILMA backend just give information about the integrated line intensity (see Cuadrado et al. 2015).
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.