Free Access

Table 2

Comparison of fit parameters and reported uncertainties (1σ in parentheses) of both noiseless and noisy simulated spectra.

Simulated Noiseless Noisy
input spectruma spectrum

Methanol
NT (cm-2) 1 × 1016 1.0 × 1016 9.91(5) × 1015
Δv (km s-1) 5 5.0 5.04(2)
T (K) 170 170.0 165.1(9)
shift (km s-1) –2 −2.0 –1.98(1)
τmax 0.0645

Methyl cyanide
NT (cm-2) 1 × 1015 1.0 × 1015 1.035(2) × 1015
Δv (km s-1) 8 8.0 7.93(2)
T (K) 50 50.0 49.0(2)
shift (km s-1) 10 10.0 10.11(1)
τmax 1.9356

Sulfur dioxide
NT (cm-2) 1 × 1014 1.0 × 1014 1.2(4) × 1014
Δv (km s-1) 15 15.0 14(4)
T (K) 120 120.0 159(59)
shift (km s-1) 0 0.0 0(1)
τmax 0.0083

Methyl formate
NT (cm-2) 1 × 1016 1.0 × 1016 1.04(3) × 1016
Δv (km s-1) 10 10.0 10.20(8)
T (K) 400 400.0 416(10)
shift (km s-1) 4 4.0 3.93(4)
τmax 0.0092

Notes.

(a)

The relative uncertainties for the results from the fit of the noiseless spectrum are on the order of 10-8, and are therefore not listed.