Free Access
Table 1
Combinations of observational data used.
Section | Data | Resolution | Error estimates |
|
|||
3.1 | IRIS 100 μm, Planck 857–217 GHz | 5.0′ | 15%, 10%, 10%, 2%, 2% |
3.2 | Herschel 250, 350, 500 μm | 37″ or 1′ | 2% + zero point uncertainties, which have mean values of |
0.39, 0.17, and 0.07 MJy sr-1 for the three bands | |||
3.3 | Herschel 160, 250, 350, 500 μm | 37″ or 1′ | 10%, 2%, 2%, 2% + a zero point uncertainty, which |
for the 160 μm band is assumed to be 1 MJy sr-1 | |||
3.5 | Herschel 250–500 μm and | ~ 37″ | Herschel 3.5%, |
Planck 857–353 GHz | Planck 10% (857–545 GHz) and 2% (353–217 GHz) |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.