Free Access

Table 1

ProtoMIRAX baseline parameters.

Detector system

Detector type: CdZnTe (CZT) Dimensions: 10 mm × 10 mm
with platinum planar contacts × 2 mm (thickness)
Number of detectors: 169 (13 × 13) Gap between detectors: 10 mm
Energy range: 30–200 keV Geometrical area: 169 cm2
Effective area @ 80 keV: 52 cm2 Time resolution: 5 μs
(through mask, at 2.7 g cm-2)

Collimator

Blade material: Cu (0.5 mm), Cell size: squares of 20-mm sides
Pb (0.5 mm), Cu (0.5 mm) External envelope: 260 mm
Blade height: 81 mm × 260 mm × 81 mm

Coded mask

Material: 1 mm-thick lead Open fraction: 0.497
Basic pattern: 13 × 13 MURA Element size: 20 mm × 20 mm
Extended pattern: 2 × 2 basic Total mask dimensions: 500 mm ×
(minus 1 line and 1 column) 500 mm × 3 mm (total thickness)
Position: 650 mm from detector plane (includes 2mm-thick acrylic substrate)

Shielding

Material: lead (external – 1.5 mm), Position: around detectors and
copper (internal – 0.5 mm) collimator (sides and bottom)

Imaging parameters

Angular resolution: 1°43′ Total (fully-coded) FOV: 21° × 21°
Source location accuracy: 10 (10σ) (14.1° × 14.1°FWHM)

Balloon gondola and flight

Gondola total mass: ~600 kg Gondola dimensions: 1.4 m × 1.4 m
Flight altitude: 42 km (2.7 g cm-2) × 1.8 m (height)
at − 23° latitude over Brazil Single flight duration: 40 h
Pointing accuracy: ~10 arcmin Star tracker precision: 10 arcsec