Free Access
Table 1
ProtoMIRAX baseline parameters.
Detector system | |
|
|
Detector type: CdZnTe (CZT) | Dimensions: 10 mm × 10 mm |
with platinum planar contacts | × 2 mm (thickness) |
Number of detectors: 169 (13 × 13) | Gap between detectors: 10 mm |
Energy range: 30–200 keV | Geometrical area: 169 cm2 |
Effective area @ 80 keV: 52 cm2 | Time resolution: 5 μs |
(through mask, at 2.7 g cm-2) | |
|
|
Collimator | |
|
|
Blade material: Cu (0.5 mm), | Cell size: squares of 20-mm sides |
Pb (0.5 mm), Cu (0.5 mm) | External envelope: 260 mm |
Blade height: 81 mm | × 260 mm × 81 mm |
|
|
Coded mask | |
|
|
Material: 1 mm-thick lead | Open fraction: 0.497 |
Basic pattern: 13 × 13 MURA | Element size: 20 mm × 20 mm |
Extended pattern: 2 × 2 basic | Total mask dimensions: 500 mm × |
(minus 1 line and 1 column) | 500 mm × 3 mm (total thickness) |
Position: 650 mm from detector plane | (includes 2mm-thick acrylic substrate) |
|
|
Shielding | |
|
|
Material: lead (external – 1.5 mm), | Position: around detectors and |
copper (internal – 0.5 mm) | collimator (sides and bottom) |
|
|
Imaging parameters | |
|
|
Angular resolution: 1°43′ | Total (fully-coded) FOV: 21° × 21° |
Source location accuracy: 10′ (10σ) | (14.1° × 14.1°FWHM) |
|
|
Balloon gondola and flight | |
|
|
Gondola total mass: ~600 kg | Gondola dimensions: 1.4 m × 1.4 m |
Flight altitude: 42 km (2.7 g cm-2) | × 1.8 m (height) |
at − 23° latitude over Brazil | Single flight duration: ≲40 h |
Pointing accuracy: ~10 arcmin | Star tracker precision: 10 arcsec |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.