Table 1
Influence of the pixel mask choice on the frequency analysis for KIC 08364249.
Fi | Frequency | Fi | Frequency | ||
d-1 | μHz | d-1 | μHz | ||
|
|||||
F1 | 1.8693 | 21.6282 | F33 | 3.8555 | 44.6083 |
F2 | 2.0095 | 23.2498 | F34 | 0.0318 | 0.3684 |
F3 | 1.9862 | 22.9802 | F35 | 0.0164 | 0.1895 |
F4 | 1.8893 | 21.8597 | F36 | 3.9690 | 45.9208 |
F5 | 1.8633 | 21.5585 | F37 | 1.7565 | 20.3222 |
F6 | 1.9194 | 22.2069 | F38 | 0.0370 | 0.4276 |
F7 | 0.0202 | 0.2342 | F39 | 3.8788 | 44.8779 |
F8 | 1.7523 | 20.2736 | F40 | 1.8684 | 21.6177 |
F9 | 1.9040 | 22.0293 | F41 | 0.0626 | 0.7248 |
F10 | 0.0123 | 0.1422 | F42 | 1.7759 | 20.5471 |
F11 | 1.9276 | 22.3029 | F43 | 3.7388 | 43.2576 |
F12 | 0.0224 | 0.2592 | F44 | 1.9380 | 22.4226 |
F13 | 0.0182 | 0.2106 | F45 | 0.0863 | 0.9984 |
F14 | 1.7293 | 20.0079 | F46 | 0.0079 | 0.0909 |
F15 | 0.0144 | 0.1672 | F47 | 3.9957 | 46.2299 |
F16 | 1.8701 | 21.6374 | F48 | 1.9855 | 22.9723 |
F17 | 3.7617 | 43.5233 | F49 | 0.0283 | 0.3276 |
F18 | 1.8463 | 21.3612 | F50 | 4.0189 | 46.4982 |
F19 | 1.8314 | 21.1890 | F51 | 4.0152 | 46.4561 |
F20 | 0.0102 | 0.1185 | F52 | 0.1203 | 1.3916 |
F21 | 0.1402 | 1.6217 | F53 | 1.9365 | 22.4055 |
F22 | 2.0642 | 23.8824 | F54 | 2.0958 | 24.2480 |
F23 | 3.9474 | 45.6710 | F55 | 1.8825 | 21.7808 |
F24 | 0.0260 | 0.3013 | F56 | 1.9114 | 22.1148 |
F25 | 0.0297 | 0.3434 | F57 | 1.9454 | 22.5081 |
F26 | 1.8577 | 21.4941 | F58 | 3.8523 | 44.5715 |
F27 | 2.0796 | 24.0613 | F59 | 1.8885 | 21.8505 |
F28 | 1.8926 | 21.8978 | F60 | 1.7235 | 19.9408 |
F29 | 0.1168 | 1.3508 | F61 | 1.7716 | 20.4972 |
F30 | 1.8754 | 21.6979 | F62 | 3.9916 | 46.1826 |
F31 | 0.0648 | 0.7498 | F63 | 1.9871 | 22.9907 |
F32 | 2.0495 | 23.7128 | F64 | 2.2176 | 25.6579 |
Notes.The uncertainty in frequency is given by the Rayleigh limit (1/T) that amounts to 0.0011 d-1 (0.0127 μHz) in this case. The barred values indicate frequencies that are not present when using our custom mask to produce the light curve but are detected when using the standard mask data. The frequencies are sorted according to the amplitude.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.