Parameter setup for the simulations.

Lscale [cm]  nd [cm-3 B0 [G]  vA [cms-1 ν [num]  k-grid

SI 3.4 × 108 105 0.174 1.2 × 108 1 1283
SII 3.4 × 108 105 0.174 1.2 × 108 10 1283
SIII 3.4 × 108 105 1.74 1.2 × 109 10 1283
SIV 3.4 × 108 105 0.00174 1.2 × 106 1 1283

Notes. The wavenumber grid is defined as k = 2π/Lscale [gridposition] . The number density nd connects the background field B0 with the Alfvén speed vA via .