Free Access

Table 1

List of input parameters of selected models.

Model label Set of input parameters

T0 = 8000 K; Ttr = 105 K; γ1 = 5; γ2 = 30
Model2 Bx(0) = 5 Gauss; M0 = 1  ×  10-5 g cm-2;
ptr = 0.03 dyn cm-2; pcen = 0.035 dyn cm-2

T0 = 5000 K; Ttr = 105 K; γ1 = 5; γ2 = 30
Model2_5000 Bx(0) = 5 Gauss; M0 = 1  ×  10-5 g cm-2;
ptr = 0.03 dyn cm-2; pcen = 0.035 dyn cm-2

T0 = 8000 K; Ttr = 105 K; γ1 = 10; γ2 = 60
Model3 Bx(0) = 5 Gauss; M0 = 5  ×  10-5 g cm-2;
ptr = 0.015 dyn cm-2; pcen = 0.13 dyn cm-2

T0 = 6000 K; Ttr = 105 K; γ1 = 10; γ2 = 60
Model3_6000 Bx(0) = 5 Gauss; M0 = 5  ×  10-5 g cm-2;
ptr = 0.015 dyn cm-2; pcen = 0.13 dyn cm-2

Notes. T0 represents the central minimum temperature; Ttr is the boundary transition-region temperature; γ1 is the exponent representing the shallower temperature gradient along the field; γ2 is the exponent prescribing the steep temperature gradient in the direction across the magnetic field lines; Bx(0) is the magnetic field strength in the middle of the thread; M0 gives the maximum column density in the middle of the thread; ptr represents the boundary gas pressure; and pcen is the central gas pressure derived from the MHS equilibrium.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.