Table 1
Bereba and Dar Al Gani 684 (here referred to as DaG) pellets along with used ions, energy, total fluence, BI slopes scaled to the initial value (i.e., slope of the irradiated spectrum – slope of the virgin one), and BI slope error.
Pellet | Ion | Energy | Tot. fluence | Scaled BI Slope | Scaled BI Slope error |
(keV) | (ions/cm2) | (μm-1) | (μm-1) | ||
|
|||||
DaG 1 | Ar+ | 200 | 8 × 1016 | 0.103 | 0.015 |
|
|||||
DaG 2 | Ar+ | 60 | 2.5 × 1017 | 0.08 | 0.015 |
|
|||||
Bereba 1 (a) | Ar+ | 200 | 4.35 × 1017 | 0.187 | 0.010 |
Bereba 1 (b) | C+ | 200 | a.b. + 3.5 × 1015 | 0.262 | 0.015 |
|
|||||
Bereba 2 (a) | Ar+ | 200 | 5 × 1016 | 0.015 | 0.010 |
Bereba 2 (b) | C+ | 200 | a.b. + 3 × 1015 | 0.095 | 0.014 |
Bereba 2 (c) | C+ | 200 | 8 × 1015 | 0.158 | 0.013 |
Bereba 2 (d) | C+ | 200 | 2.3 × 1016 | 0.258 | 0.018 |
|
|||||
DaG 3 (a) | Ar+ | 200 | 5 × 1016 | 0.040 | 0.015 |
DaG 3 (b) | C+ | 200 | a.b. + 3 × 1015 | 0.138 | 0.015 |
DaG 3 (c) | Ar+ | 200 | a.b. + 2 × 1016 | 0.168 | 0.014 |
DaG 3 (d) | C+ | 200 | a.b. + 8 × 1015 | 0.363 | 0.019 |
DaG 3 (e) | C+ | 200 | 1.3 × 1016 | 0.506 | 0.027 |
Notes. When considering consecutive irradiation steps with the same ion, the total fluence reached with that ion is reported. When a pellet was consecutively irradiated with different ions, “a.b.” (=as before) appears in the row where the irradiation with the new ion is considered. In that case, the fluence following the “a.b.” label is the one with the new ion (to be added to the previous value).