Table 5: PIN count rates measured in the 12-40 keV and 40-60 keV bands. The quoted errors are 1$\sigma $ statistical errors.
Seq Energy range Exposure Data NXB (Data-NXB) (Data-NXB)/NXB
    [s] $\left[{\rm c~s^{-1}}\right]$ $\left[{\rm c~s^{-1}}\right]$ $\left[{\rm c~s^{-1}}\right]$ %
801013010 12-40 keV 56 698 $0.5180 \pm 0.0030$ $0.4754 \pm 0.0009$ $0.0426 \pm 0.0031$ $8.96 \pm 0.67$
801013020 12-40 keV 64 922 $0.5223 \pm 0.0028$ $0.4709 \pm 0.0008$ $0.0514 \pm 0.0030$ $10.92 \pm 0.63$
801013010+801013020 12-40 keV 121 620 $0.5203 \pm 0.0021$ $0.4730 \pm 0.0006$ $0.0473 \pm 0.0022$ $10.00 \pm 0.46$
801013010 40-60 keV 56 698 $0.0497 \pm 0.0009$ $0.0499 \pm 0.0003$ $-0.0002 \pm 0.0010$ $-0.44 \pm 1.96$
801013020 40-60 keV 64 922 $0.0497 \pm 0.0009$ $0.0495 \pm 0.0003$ $0.0002 \pm 0.0009$ $0.43 \pm 1.85$
801013010+801013020 40-60 keV 121 620 $0.0497 \pm 0.0006$ $0.0497 \pm 0.0002$ $0.0000 \pm 0.0007$ $0.03 \pm 1.35$