Table 1: Values of parameters characterizing the X-ray ejection.
Time Tempe- Emission Visible Total Electron Electron Mass, M
  rature, T measure, EM volume, $V_{\rm {vis}}$ volume, $V_{\rm {tot}}$ density, $n_{\rm {e}}$ pressure, $p_{\rm {e}}$  
UT [106 K] [1047 cm-3] [1029 cm3] [1029 cm3] [109 cm-3] [dyn cm-2] [1014 g]
05:29:28a 7.8 1.7 0.37-0.67 0.78-1.1 1.6-2.1 1.7-2.3 2.8-2.9
05:29:46a 7.8 2.0 0.37-0.69 0.78-1.2 1.7-2.3 1.8-2.5 3.0-3.3
05:30:06a 7.9 2.3 0.38-0.71 0.78-1.2 1.8-2.4 1.9-2.7 3.1-3.5
05:30:28a 7.9 2.6 0.40-0.76 0.79-1.3 1.8-2.6 2.0-2.8 3.3-3.9
05:30:50a 7.9 2.9 0.44-0.85 0.84-1.4 1.8-2.6 2.0-2.8 3.6-4.3
05:31:14 8.2 2.7 0.51-0.99 0.94-1.6 1.7-2.3 1.9-2.6 3.6-4.4
05:31:36 8.1 2.9 0.62-1.2 1.1-1.9 1.6-2.2 1.8-2.4 3.9-4.9
05:32:00 7.9 3.0 0.78-1.5 1.3-2.3 1.4-2.0 1.6-2.2 4.2-5.5
05:32:22 7.9 3.3 0.99-1.8 1.6-2.8 1.4-1.8 1.5-2.0 4.8-6.3
05:32:46 7.8 3.4 1.3-2.4 2.0-3.5 1.2-1.6 1.3-1.7 5.4-7.0
05:33:08 7.7 3.6 1.7-3.0 2.6-4.4 1.1-1.5 1.2-1.5 6.1-8.0
05:33:32 7.6 3.8 2.3-4.0 3.3-5.6 0.98-1.3 1.0-1.3 7.1-9.2
05:33:54 7.6 3.7 3.1-5.1 4.3-7.1 0.85-1.1 0.88-1.1 7.8-10.0
05:34:18 7.4 3.8b 4.2-6.8 5.7-9.2 0.75-0.95 0.76-0.97 9.0-11.4
05:34:40 7.3 3.6b 5.6-8.7 7.3-11.6 0.64-0.80 0.64-0.80 9.7-12.3
05:35:04 7.1 3.3b 7.5-11.5 9.7-15.0 0.53-0.66 0.52-0.65 10.6-13.3
05:35:26 7.0 2.9b 9.9-14.8 12.4-18.9 0.45-0.55 0.43-0.53 11.3-14.0
05:35:50 7.0 2.6b 13.2-19.3 16.2-24.2 0.36-0.44 0.35-0.43 11.9-14.7
a The signal from feature B was included. Actual temperature values should be somewhat higher, whereas actual values of emission measure, electron density, electron pressure and mass should be somewhat lower.
b The signal from the part of the X-ray ejection that runs away outside the HN field of view was added from the SXT QN AlMg images (so-called Quarter Normal resolution, QN - pixel size $9\hbox{$.\!\!^{\prime\prime}$ }8$ $\times $ $9\hbox{$.\!\!^{\prime\prime}$ }8$).

Source LaTeX | All tables | In the text