Open Access

Table 2

Parameters of fits to lines observed in Chamaeleon C2.

Transition vo (MHz) t (h) σ (mK) Tmbdυ (mK km s−1) VLSR (km s−1) V (km s−1)
HC3N (2 − 1) 18 196.2300 22.0 3.4 209. (12.) 3.86 (0.01) 0.89 (0.04)
c-C3H2(110 − 101) 18 343.1430 22.0 3.2 344. (3.5) 3.82 (0.01) 0.92 (0.01)
HC5N (7 − 6) 18 638.6164 22.0 3.9 56.2 (4.0) 3.83 (0.04) 0.82 (0.01)
C4H (2 − 1, 5/2 − 3/2, 2 − 1) 19 014.7204 22.0 3.7 15.9 (4.1) 4.23 (0.11) 0.91 (0.24)
C4H (2 − 1, 5/2 − 3/2, 3 − 2) 19 015.1435 22.0 3.7 23.0 (4.3) 4.20 (0.10) 1.08 (0.24)
C4H (2 − 1, 3/2 − 1/2, 2 − 1) 19 054.4762 22.0 3.7 40.5 (7.8) 3.93 (0.16) 1.60 (0.35)
c-C3HD (110 − 101) 19 418.7272 22.0 3.5 48.7 (5.0) 4.11 (0.06) 1.42 (0.21)
HC5N (8 − 7) 21 301.2614 22.0 3.4 92.9 (4.7) 3.95 (0.01) 0.79 (0.04)
c-C3H2 (220 − 211) 21 587.4010 22.0 3.2 −210. (3.0) 4.04 (0.01) 0.88 (0.02)
CCS (1 − 2, 2 − 1) 22 344.0308 22.0 2.9 252. (2.7) 3.85 (0.01) 0.81 (0.01)
15NH3 (1,1) 22 624.9295 22.0 3.3 <11.0(a)
C3S (4 − 3) 23 122.9836 18.5 3.9 119. (3.4) 4.27 (0.01) 0.78 (0.03)
NH3 (1,1) 23 694.4955 18.5 3.1 3751 (29.) 4.22 (0.01) 0.69 (0.01)
HC5N (9 − 8) 23 963.9007 18.5 3.3 95.1 (3.0) 4.23 (0.01) 0.73 (0.09)
NH3 (2, 2) 23 722.6333 18.5 3.4 192. (30.) 4.23 (0.01) 0.70 (0.01)
NH3 (3, 3) 23 870.1292 18.5 3.5 <11.1(a)

U22902 22 902.037 22.0 3.6 26.9 (3.6) 4.16 (0.06) 0.098 (0.17)

Notes. Entries in the table are molecular transition, rest frequency, total observing time including the two polarizations, final rms in a single spectrometer channel in the vicinity of the line, integrated line intensity (opacity corrected for the HFS fits; see Sect. 2.5.3 of the CLASS user manual: https://www.iram.fr/IRAMFR/GILDAS/doc/pdf/class.pdf), line velocity, and line width. Integrated line intensities have been corrected for the beam efficiency but not for the coupling to the source. Values in parenthesis are 1σ fit uncertainties. (a) The 3σ upper limit integrated over a 2.5−5.5 km s−1 velocity range. An unidentified ~7.5σ feature is detected at 22.902 GHz, which is not present in the Cha-MMS1 spectrum. The opacity of the main NH3 (1,1) hyperfine component implied by the HFS fit is 2.85 ± 0.04.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.