Open Access

Table 2

LTE slab model best-fit parameters.

Species N (cm−2) [N/N H2] (a) T (K) R (au) 𝒩 (mol.)
source A+B
12CO2 (17) (−7) (2) (2) 3.7 (48)
13CO2 (b) <1.2 (16) <1.4 (−8) 2.6 (47)
C2H2 (16) (−8) (2) (1) 1.0 (46)
13CCH2 (c) <8.5 (15) <1.0 (−8) 1.1 (45)
HCN <2.7 (19) <3 1 (−5) <1 0 (2) >4.0 (2) 2.4 (49)
OH (d) <7.9 (17) <9.4 (−7) (3) >2.0(0) 4.0 (44)
source A

CO (e) <5 6(18) <6.3 (−6) (3) >8.8 (−2) 4.7 (42)
source B

H2O (f) (18) (−5) (2)
source S1

CO (e) <5.4 (17) <5.4 (−7) (3) >2.2 (−1) 1.1 (43)
OH <3.8(18) <3.8 (−6) (3) >1.2 (0) 1.4 (45)

Notes. All numbers are written in the format a (b) = a × 10b, with 1 sigma confidence intervals where appropriate. (a)See discussion of uncertainties and caveats on the column density ratios in Sects. 3.2 and 4.6. (b)Fitting performed with T and R fixed to best-fit values for 12CO2. (c)Fitting performed with T and R fixed to best-fit values for C2H2.(d)Highly non-LTE behaviour likely, see Sect. 4.5. (e)Best-fit temperature can be overestimated, see Sect. 4.4. (f)Seen in absorption.