Free Access
Table A.1
Addition to Table 2 in Amodeo et al. (2016): information on the sizes and gas content of these clusters.
Object | z | R 500 | f gas,500 | Reference for redshift |
− | − | [kpc] | [fraction] | − |
|
||||
MACS0159.8-084 | 0.405 | 1379 ± 111 | 0.11 ± 0.02 | Kotov & Vikhlinin (2006) |
MACSJ2228.5+20 | 0.412 | 1418 ± 156 | 0.13 ± 0.03 | Böhringer et al. (2000) |
MS1621.5+2640 | 0.426 | 1298 ± 127 | 0.1 ± 0.02 | Stocke et al. (1991) |
MACSJ1206.2-08 | 0.44 | 1874 ± 128 | 0.08 ± 0.01 | Borgani et al. (2001) |
MACS-J2243.3-0 | 0.447 | 1335 ± 137 | 0.16 ± 0.03 | Coble et al. (2007) |
MACS0329.7-021 | 0.45 | 1264 ± 113 | 0.12 ± 0.04 | Allen et al. (2004) |
RXJ1347.5-1145 | 0.451 | 1756 ± 134 | 0.1 ± 0.02 | Schindler et al. (1995) |
V1701+6414 | 0.453 | 707 ± 48 | 0.26 ± 0.04 | Wang & Walker (2014) |
MACS1621.6+381 | 0.465 | 1349 ± 242 | 0.09 ± 0.04 | Edge et al. (2003) |
CL0522-3624 | 0.472 | 754 ± 271 | 0.11 ± 0.11 | Mullis et al. (2003) |
MACS1311.0-031 | 0.494 | 1420 ± 241 | 0.06 ± 0.02 | Allen et al. (2004) |
MACS-J2214.9-1 | 0.503 | 1275 ± 253 | 0.14 ± 0.06 | Bonamente et al. (2006) |
MACS911.2+1746 | 0.505 | 1338 ± 140 | 0.1 ± 0.07 | Ebeling et al. (2007) |
MACSJ0257.1-23 | 0.505 | 1293 ± 260 | 0.12 ± 0.05 | Ebeling et al. (2007) |
V1525+0958 | 0.516 | 1259 ± 191 | 0.05 ± 0.01 | Mullis et al. (2003) |
MS0015.9+1609 | 0.541 | 1381 ± 128 | 0.13 ± 0.02 | Stocke et al. (1991) |
CL0848.6+4453 | 0.543 | 701 ± 394 | 0.13 ± 0.2 | Takey et al. (2011) |
MACS1423.8+240 | 0.543 | 1041 ± 16 | 0.13 ± 0.01 | Ebeling et al. (2007) |
MACSJ1149.5+22 | 0.544 | 1187 ± 141 | 0.19 ± 0.04 | Ebeling et al. (2007) |
MACSJ0717.5+3745 | 0.546 | 1409 ± 59 | 0.17 ± 0.02 | Ebeling et al. (2007) |
CL1117+1744 | 0.548 | 568 ± 106 | 0.2 ± 0.09 | Wen et al. (2009) |
MS0451.6-0305 | 0.55 | 1699 ± 229 | 0.07 ± 0.03 | Gioia & Luppino (1994) |
MS2053.7-0449 | 0.583 | 1239 ± 367 | 0.04 ± 0.02 | Stocke et al. (1991) |
MACS-J2129.4-0 | 0.589 | 1155 ± 228 | 0.15 ± 0.07 | Ebeling et al. (2007) |
MACS-J0647.7+7 | 0.591 | 1762 ± 333 | 0.06 ± 0.02 | Ebeling et al. (2007) |
CL1120+4318 | 0.6 | 894 ± 208 | 0.16 ± 0.08 | Romer et al. (2000) |
CLJ0542.8-4100 | 0.64 | 801 ± 68 | 0.13 ± 0.03 | De Propris et al. (2007) |
LCDCS954 | 0.67 | 567 ± 98 | 0.16 ± 0.07 | Gonzalez et al. (2001) |
MACS0744.9+392 | 0.698 | 994 ± 93 | 0.17 ± 0.04 | Ebeling et al. (2007) |
SPT-CL0001-5748 | 0.7 | 902 ± 261 | 0.12 ± 0.08 | Vikhlinin et al. (1998) |
V1221+4918 | 0.7 | 738 ± 127 | 0.15 ± 0.07 | Mantz et al. (2014) |
RCS2327.4-0204 | 0.704 | 1547 ± 112 | 0.08 ± 0.01 | Gralla et al. (2011) |
SPT-CLJ2043-5035 | 0.72 | 1348 ± 255 | 0.07 ± 0.02 | Song et al. (2012) |
ClJ1113.1-2615 | 0.73 | 747 ± 178 | 0.06 ± 0.04 | Perlman et al. (2002) |
CLJ2302.8+0844 | 0.734 | 1042 ± 207 | 0.06 ± 0.02 | Perlman et al. (2002) |
SPT-CL2337-5942 | 0.775 | 1590 ± 414 | 0.04 ± 0.02 | Vanderlinde et al. (2010) |
RCS2318+0034 | 0.78 | 1681 ± 484 | 0.02 ± 0.01 | Hicks et al. (2008) |
MS1137.5+6625 | 0.782 | 994 ± 203 | 0.06 ± 0.03 | Gioia & Luppino (1994) |
RXJ1350.0+6007 | 0.81 | 577 ± 71 | 0.17 ± 0.05 | Holden et al. (2002) |
RXJ1716.9+6708 | 0.813 | 646 ± 89 | 0.15 ± 0.05 | Henry et al. (1997) |
EMSS1054.5-0321 | 0.831 | 1308 ± 227 | 0.06 ± 0.02 | Gioia et al. (2004) |
CLJ1226.9+3332 | 0.888 | 1752 ± 409 | 0.04 ± 0.02 | Ebeling et al. (2001) |
XMMUJ1230+1339 | 0.975 | 792 ± 309 | 0.08 ± 0.07 | Fassbender et al. (2011) |
J1415.1+3612 | 1.03 | 772 ± 259 | 0.08 ± 0.05 | Ellis & Jones (2004) |
SPT-CL0547-5345 | 1.067 | 779 ± 188 | 0.14 ± 0.08 | High et al. (2010) |
SPT-CLJ2106-584 | 1.132 | 963 ± 254 | 0.13 ± 0.06 | Foley et al. (2011) |
RDCS1252-29 | 1.235 | 533 ± 124 | 0.13 ± 0.08 | Rosati et al. (2004) |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.