All Tables
- Table 1:
Relevant parameters of the observed sample of Cepheids, sorted by increasing period.
- Table 2:
Relevant parameters of the calibrators.
- Table 11:
Order 0.
Cepheid average angular diameters and distances derived from the VINCI
interferometric measurements, assuming a constant diameter model (
),
The average diameter
is taken from Gieren et al. (1998).
Two error bars are given in brackets for the angular diameter: the statistical dispersion
and the calibration systematics.
The uncertainty mentioned for the distance d is the quadratic sum
of the statistical, calibration and P-R a priori diameter errors, the last two
being systematic in nature. The three types of errors are also reported
separately in brackets.
The results for
Car
are mentioned only for completeness, but are not meant to be used
for further analysis, as our observations are inconsistent with a constant
diameter model.
- Table 12:
Order 1.
Cepheid angular diameters and distances, assuming the average diameter
of Gieren et al. (1998). The diameter variation curve
is integrated from the radial velocity curve.
Only the distance is ajusted by the fitting procedure. The error bars on d are
given as in Table 11.
- Table 13:
Order 2.
Cepheid average angular diameters and distances determined through the
application of the modified BW method. The only input is
the diameter variation curve
derived from the integration of the radial
velocity. The distance and average angular diameter are
ajusted simultaneously. The statistical and systematic errors on d are
listed separately in brackets.
- Table 14:
Average UD angular diameter of
Aql and
Gem
from the litterature, and the associated conversion factor
from the linear limb darkening
coefficients of Claret (2000). References:
(1) Armstrong et al. (2001)
and Nordgren et al. (2000),
(2) Lane et al. (2002),
(3) this work.
- Table 3:
VINCI/VLTI angular diameter measurements of X Sgr.
- Table 4:
Angular diameter measurements of
Aql.
- Table 5:
Angular diameter measurements of W Sgr.
- Table 6:
Angular diameter measurements of
Dor.
- Table 7:
VINCI/VLTI and FLUOR/IOTA angular diameter measurements of
Gem.
No systematic calibration error is given for FLUOR/IOTA values (negligible compared to the
statistical uncertainty). The baseline is given for the VINCI/VLTI observations (in m), while the spatial frequency (in italic)
is listed for the measurements obtained with FLUOR, expressed in cycles/arcsec.
- Table 8:
Angular diameter measurements of Y Oph.
- Table 9:
Angular diameter measurements of
Car.
- Table 10:
Published linear diameter estimates, expressed in
.