Table 1:
INTEGRAL payload: key parameters.
Parameter |
SPI |
IBIS |
Energy range |
18 keV-8 MeV |
15 keV-10 MeV |
Detector |
19 Ge detectors, each ( )
cm |
16384 CdTe dets, each (
)
mm |
|
cooled @ 85 K |
4096 CsI dets, each (
)
mm |
Detector area (cm2) |
500 |
2600 (CdTe), 2890 (CsI) |
Spectral resolution (FWHM) |
3 keV @ 1.7 MeV |
8 keV @ 100 keV |
Continuum sensitivity |
5.5
10-6 @ 100 keV |
6
10-7 @ 100 keV |
(photons cm-2 s-1 keV-1) |
1.2
10-6 @ 1 MeV |
5
10-7 @ 1 MeV |
(
,
3 ,
106 s) |
|
|
Line sensitivity |
3.3
10-5 @ 100 keV |
1.9
10-5 @ 100 keV |
(photons cm-2 s-1) |
2.4
10-5 @ 1 MeV |
3.8
10-4 @ 1 MeV |
(3 ,
106 s) |
|
|
Field of view (fully coded) |
16
(corner to corner) |
9
9 |
Angular resolution (FWHM) |
2.5
(point source) |
12 |
Source location (radius) |
1.3
(depending on source strength) |
1
(for 10
source) |
Absolute timing accuracy (3 ) |
200 s |
200 s |
Mass (kg) |
1309 |
746 |
Power [max/average] (W) |
385/110 |
240/208 |
Parameter |
JEM-X |
OMC |
Energy range |
4 keV-35 keV |
500 nm-600 nm |
Detector |
Microstrip Xe/CH4-gas detector (1.5 bar) |
CCD + V-filter |
Detector area (cm2) |
500 for each of the two JEM-X detectorsa |
CCD: (2061
1056) pixels |
|
|
Imaging area (1024
1024) pixels |
Spectral resolution (FWHM) |
2.0 keV @ 22 keV |
- |
Continuum sensitivityb |
1.2
10-5 @ 6 keV |
- |
(photons cm-2 s-1 keV-1) |
1.3
10-5 @ 30 keV |
- |
(3 ,
106 s) |
|
|
Line sensitivityb |
1.9
10-5 @ 6 keV |
- |
(photons cm-2 s-1) |
8.5
10-5 @ 30 keV |
- |
(3 ,
106 s) |
|
|
Limiting magnitude (mag) |
- |
17.8 |
(3 ,
5000 s) |
|
|
Field of view (fully coded) |
4.8 |
5
5 |
Angular resolution (FWHM) |
3 |
25  |
10
source location (radius) |
30  |
6  |
Absolute Timing accuracy (3 ) |
200 s |
1 s |
Mass (kg) |
65 |
17 |
Power [max/average] (W) |
50/37 |
20/17 |